NPA Never Paint Again | For a free survey and quote to repair and paint your home, call 0800 970 4928, or click here...
 
 

Technical specifics of NPA exterior wall coatings

Architect, specifier or construction chemical professional?

Here is some technical information and a brief explanation of each element of the NPA exterior wall coating system


TYPICAL DRY FILM THICKNESS
Variable, although generally a film of NPA exterior coating is about 20 times the thickness of a normal paint film.

ELONGATION
Flexible, in fact the NPA exterior wall coating system is so flexible, it can be bent around 360 degrees! Click here for a demonstration.

SERVICE TEMPERATURE
-15º C to + 80ºC.
The NPA exterior wall system can be applied in freezing temperatures and in very hot weather too!

ACCELERATED WEATHERING
M.O.D Def. 1053 - 1000 Hours
No defects or change in flexibility meaning that our claims of long life have been tested against this criteria and it "does what is says on the tin!"

CHEMICAL AND DAMP RESISTANCE
Sulphur dioxide (No effect). The NPA system resist the growth of damp, algae and mould, meaning that of your walls are green, they wont be any more!

FLASH POINT
40°C

APPROXIMATE SOLIDS CONTENTS

68% by weight

52% By Volume

Specific gravity: 1.30

TSC (approx) 73% B.S 1391:1952

Viscosity (RTT) 54 Poise

DRYING TIME

> 8 hours (touch dry) under normal conditions

The NPA system is so thick and substantial that it can take up to 2 to 3 weeks to fully cure and dry. Customers must avoid placing ladders or any other objects onto the wall surface during this time.

IMPACT RESISTANCE

Internal test suggests that the film will tolerate a 5mm indentation without damage. The NPA system is designed to be a thick protective coat all over your home, resisting the harsh weather, which breaks down normal masonry paint.

PACKAGING GROUP
Three

PACK SIZE

The NPA system is only available to the trade and come in 5, 10, 15, 20, 25 litres pack sizes for your convenience.